With GB 47372-2026, China's mobile power safety specification, taking effect on 1 April 2027, battery management has moved from simple protection to voltage, current and temperature acquisition, cell balancing and fault logging. Injoinic has introduced the IP3561Q, an analog front end for 2- to 5-series lithium-ion and lithium-polymer packs that pairs with an external MCU to form the BMS.

The device carries separate 16-bit voltage and current ADCs. It measures individual cell voltages, total pack voltage, PACK-terminal voltage, current and temperature, with a maximum cell-voltage error of 8mV. Up to four NTC channels are supported, and with a 2mOhm sense resistor the part can measure currents up to 50A. Protection is implemented in hardware independent of the MCU: overcharge, over-discharge, two-level discharge over-current, charge over-current, short circuit, charge and discharge high/low temperature, and broken-wire detection, all with configurable thresholds and delays. An integrated charge pump and high-side NMOS driver let the chip control external charge and discharge FETs directly.

For pack-level consistency, the IP3561Q includes passive balancing switches operable either automatically or under MCU control, with balancing current extendable through external circuitry. Host communication runs over I2C at 100kHz or 400kHz with CRC8 checking, a watchdog and interrupt signalling; a 32-bit counter tracks power-on time. Five operating modes cover normal, idle, sleep, PD and shipping, with typical normal-mode draw of 150uA falling to 2uA in PD and shipping modes to limit storage and transport drain. An on-chip 3.3V/25mA LDO can supply the host MCU, and the package is a 4 x 4mm QFN32.

For power bank developers, the split architecture keeps safety cut-offs in silicon while leaving gauge algorithms and reporting to firmware — a practical route to multi-string, high-capacity designs under the new standard.